All Forced Air Systems: Conventional filters on forced-air systems should be checked monthly and cleaned or replaced as needed. Electronic filters should be checked monthly and cleaned as needed. The manufacturers instructions should be followed carefully. Care should be taken to ensure the interior components are installed in the correct orientation after cleaning.

Noisy blower sections should be brought to the attention of a technician.

Water levels in humidifiers should be checked and adjusted monthly. Interior components should be replaced on an as needed basis. The pad on drum type humidifiers should be replaced annually. The water supply to humidifiers should be shut off for the summer months and activated for the heating months. On systems with air conditioning or a heat pump, the damper in the humidifier ductwork should be closed during the cooling season.

All Hot Water Systems: Radiators and convectors should be inspected annually for leakage (particularly at the valves). Radiators should be bled of air annually, and as necessary during the heating season.

Circulating pumps should be lubricated twice during the heating season. Expansion tanks should be drained annually.

Electric Heat: Electric furnaces and boilers should be inspected by a qualified technician every year to ensure that all the components are operating properly and no connections are loose or burned. The fuses or circuit breakers in some electric systems can be checked by the homeowner.

Electric baseboard heaters should be inspected to ensure an adequate clearance from combustibles. Baseboard heaters which have been mechanically damaged should be repaired or replaced.

Oil Furnaces and Boilers: Oil systems should be checked by a qualified technician on an annual basis. Oily soot deposits at registers of forced air systems may indicate a cracked heat exchanger. A technician should be contacted.

The exhaust pipe from the furnace or boiler should be checked for loose connections or corroded sections. The barometric damper on the exhaust pipe should rotate freely. The chimney clean out should be cleared of any debris. The oil tank should be inspected for leaks. Soot on the front of the furnace or boiler may indicate a draft or combustion problem. A technician should be contacted.

Gas Furnaces and Boilers: If gas odors can be detected, call the gas company immediately. Do not turn on any electrical equipment or use anything with an open flame.

Gas furnaces and boilers should be cleaned and serviced annually. The exhaust pipe should be checked for loose or corroded sections. The chimney clean out should be cleared of any debris. The heat shield (located where the burner enters the heat exchanger) should be checked to ensure that it is not loose or corroded. Burn marks around the heat shield may indicate a draft or combustion problem. A technician should be contacted.
The information and recommendations contained here in are, to the best of A thru Z Home Inspection, Inc. knowledge and belief, are accurate and reliable. This document is offered in good faith. A thru Z Home Inspection, Inc. does not warrantee or guarantee accuracy, reliability, or completeness. It is the user's responsibility to satisfy himself as to the suitability and completeness of such information for his own particular use. We do not accept liability for any loss or damage that may occur from this information.
ASHI CERTIFIED INSSPECTOR ID # 210605
a_thru_z_home_webpage045048.gif a_thru_z_home_webpage045047.gif a_thru_z_home_webpage045046.gif a_thru_z_home_webpage045045.gif a_thru_z_home_webpage045044.gif a_thru_z_home_webpage045043.gif a_thru_z_home_webpage045042.gif a_thru_z_home_webpage045041.gif a_thru_z_home_webpage045040.gif a_thru_z_home_webpage045039.gif a_thru_z_home_webpage045038.gif a_thru_z_home_webpage045037.gif a_thru_z_home_webpage045036.gif a_thru_z_home_webpage045035.gif a_thru_z_home_webpage045034.gif a_thru_z_home_webpage045033.gif a_thru_z_home_webpage045032.gif a_thru_z_home_webpage045031.gif a_thru_z_home_webpage045030.gif a_thru_z_home_webpage045029.gif a_thru_z_home_webpage045028.gif a_thru_z_home_webpage045027.gif a_thru_z_home_webpage045026.gif a_thru_z_home_webpage045025.gif a_thru_z_home_webpage045024.gif a_thru_z_home_webpage045023.gif a_thru_z_home_webpage045022.gif a_thru_z_home_webpage045021.gif a_thru_z_home_webpage045020.gif a_thru_z_home_webpage045019.gif a_thru_z_home_webpage045018.gif a_thru_z_home_webpage045017.gif a_thru_z_home_webpage045016.gif a_thru_z_home_webpage045015.gif a_thru_z_home_webpage045014.gif a_thru_z_home_webpage045013.gif a_thru_z_home_webpage045012.gif a_thru_z_home_webpage045011.gif a_thru_z_home_webpage045010.gif a_thru_z_home_webpage045009.gif a_thru_z_home_webpage045008.gif a_thru_z_home_webpage045007.gif a_thru_z_home_webpage045006.gif a_thru_z_home_webpage045005.gif a_thru_z_home_webpage045004.gif a_thru_z_home_webpage045003.gif
Next Page
Service Area
Previous Page
Home
About Us
Services
Contact Us
F.A.Q.s
Pricing
About ASHI
Testimonials
Links
What is a WDI
Well Disinfection
Real Estate Professionals
Inspection vs Appraisal
Pre-Sale Inspection
Commercial Inspections
Homeowner Maintenance Inspection
Tips For Selling Your Home
Older Homes Info.
Fuel tanks
NEW CONSTRUCTION
Log Homes Info.
 Private Wells Info.
Widlife Info.
Ground Fault Circuit Interrupters
Carbon Monoxide Detectors
Smoke Detectors
Electrical Info.
Structure Info.
Heating Systems Info.
Air Conditioning Systems Info.
Attic Info.
Fireplace/Wood Stove Info.
Labeling Main Shut-Offs
Prebuilt Homes
Lead Info.
Asbestos
Home Safety
Energy Efficiency
Awards Won
Septic Dye Test
Mold Sampling
Water Test
Basement and Crawlspace Info.
a_thru_z_home_webpage045002.gif
EIFS Info.
a_thru_z_home_webpage045001.gif
Awards Won
Connecticut Home Inspector license # HOI.0000581.
a%20thru%20z%20home%20detective_searching_clues_lg_nwm.gif
TM
Documents